Settings/settings refresh timer

From Snom User Wiki

Jump to: navigation, search
WEB USER INTERFACE
V7 from 7.1.36/7.3.10: Advanced - Update(Section): Settings refresh timer
V8: Advanced - Update(Section): Settings refresh timer
PHONE USER INTERFACE
N/A
FIRMWARE VERSIONS
V7  V8  
Starting versions: 7.1.36, 7.1.36, 7.3.10, 7.3.10
XML CONFIGURATION
<settings_refresh_timer perm="PERMISSIONFLAG">VALIDVALUE</settings_refresh_timer>
DESCRIPTION
If a value greater than 0 is set (=number of seconds) the phone configuration will be requested from the setting server after the time has elapsed. After fetching the settings from the "setting server URL" they will be applied and the timer will be reset to the latest received value.
VALIDVALUE
Integer values e.g. 3600 (seconds)
DEFAULTVALUE
0
FURTHER INFORMATION
Firmware