Settings/inactive stream alert info text

From Snom User Wiki

Jump to: navigation, search
WEB USER INTERFACE
n/a
PHONE USER INTERFACE
n/a
FIRMWARE VERSIONS
V8  
Starting versions: 8.7.5.(37)
XML CONFIGURATION
<inactive_stream_alert_info_text idx="INDEX" perm="PERMISSIONFLAG">VALIDVALUE</inactive_stream_alert_info_text>
DESCRIPTION
When the info parameter of the Alert-Info header contains the text specified in this setting, the audio stream will be set to inactive on accepting the call. This is useful for reducing the connect time when transferring calls from a queue to an agent. For example:
Alert-Info: <http://www.notused.invalid>;info=queue
Setting this setting to "queue" would suppress the audio stream in the initial INVITE containing the above header.
VALIDVALUE
any text
DEFAULTVALUE
empty
FURTHER INFORMATION
Ringtone:Alert Info