FAQ/What is the maximum number of m3 base stations that can be used on one site
From Snom User Wiki
< FAQ
| Languages: English • Deutsch |
Answer
DECT is based on 120 channels (or time-slots). As you need two channels for one handset (one for sending one for receiving) you could have in theory 60 handsets running in the same coverage area (30-50m indoor; up to 300m outdoor) From this point of view up to 20 base stations (with 3 concurrent calls per base --> 20 base stations x 3 calls = 60 channels) could be used but as signaling and synchronization also requires channels (timeslots), 10 base stations could be realistic. Base stations should not be placed close to each other (as there might be radio interferences).
